Digital test bench

Medical AI, measured before it is trusted.

An independent, repeatable way to measure a medical AI against what really happened to patients, before it goes live and again after every update.

Pilot programmeThe test bench is being built. Its first proof of concept is an early warning for sepsis.
Why a test bench

A claim is not a measurement.

  • Measured by its makers

    A medical AI is usually measured by the people who built it, on data like the data it learned from.

  • Other patients, other data

    The patients of a hospital differ from that data: in age, in illness, and in how care is given and recorded.

  • Every update changes the model

    A model changes with every update, and its performance can change with it.

So performance has to be measured independently, on other data, again and again.

How it works

Every prediction, checked against the real course.

The test bench replays past cases. The AI under test sees only what was known at the time, and each of its predictions is compared with what then happened to the patient.

  1. Past clinical data

    Only what was known up to the moment of prediction, for example 6 hours before.

  2. The AI under test

    It receives the same data it would receive in the hospital and makes its prediction.

  3. Its prediction

    A warning, yes or no, and a risk score.

  4. What really happened

    The clinically confirmed later course of each patient. This is the reference.

  5. The test bench compares

    Prediction and reference, case by case, in three test modules.

    Test modules

    • Model performanceSensitivity, specificity, false alarms, and stability when data is missing.
    • Group comparisonPerformance in subgroups such as age, sex and pre-existing conditions, to spot a group that is put at a disadvantage.
    • Clinical riskWhat the errors mean medically: missed cases and false alarms, the possible harm, and an overall view.
  6. The result

    What the comparison found, and what it means.

    • Assessment reportThe findings of every module, each linked to its evidence.
    • Warning signalsWhere the AI falls short, and for which patients.
    • Expert reviewClinicians judge the findings, look for their causes and make recommendations.
  7. Repeat after every update

    Each new model version runs through the same tests.

  8. Continuous monitoring in operation

    Once the AI is in use, the tests keep running and warn when quality drops.

Try it

Move the threshold. See what changes.

A synthetic cohort of 10,000 patients, 10% of whom develop the condition. A fictional AI gives each patient a risk score. You decide at which score it raises an alert.

Illustration with synthetic data. Not a test result.

An alert is raised for every patient whose risk score is at or above this value.

At this threshold

  • 81%

    Sensitivity

    Of 100 patients who had the condition, the AI warned for 81.

  • 75%

    Specificity

    Of 100 patients who did not have the condition, 75 received no alert.

  • 26%

    Positive predictive value

    Of 100 alerts, 26 went to a patient who had the condition.

  • 31

    Alerts per 100 patients

    True alerts: 8.1. False alarms: 23.

  • 19

    Missed cases per 1,000 patients

    Patients who had the condition and received no warning.

ROC curve

Each threshold is one point on the curve: the share of patients with the condition who get an alert, against the share of patients without it who get one. The marked point is your threshold.

Sensitivity

False alarm rate (1 − specificity)

Sensitivity by group

The same threshold, four separate synthetic groups: the age groups count only patients without a pre-existing condition. The line marks the value for all patients.

All patients81%

  • Aged 18 to 4490%
  • Aged 45 to 6484%
  • Aged 65 and over82%
  • With a pre-existing condition71%

Lowest sensitivity at this threshold: With a pre-existing condition. The AI warns for 71% of its patients with the condition, 10.0 percentage points below the 81% for all patients.

Alarm burden

Accuracy, turned into workload.

Sensitivity and specificity sound abstract. Enter the numbers of a ward or a hospital and see the alerts, false alarms and staff time they lead to.

Illustration with synthetic data. Not a test result.

Your numbers

per dayAllowed: 10 to 2000
%Allowed: 0.5 to 30
%Allowed: 50 to 99
%Allowed: 50 to 99.5
minAllowed: 1 to 30

What they lead to

  • 41.3Alerts per day
  • 28.5False alarms per day
  • 9.5False alarms per shift of 8 hours
  • 31%Share of alerts that are true
  • 2.3Cases missed per day
  • 5.5Staff hours per day

A simplified model: each patient is checked once a day. A real evaluation measures these figures on the hospital’s own data.

In an engagement, health economists turn these hours into cost.

Clinical & Technical AI Evaluation

What the report contains

One assessment report, traceable line by line.

What a report from the test bench covers. Clinicians review it before it is handed over.

Assessment report

Contents

  1. Scope and data used

    The question, the version of the AI tested, and the data it was tested on.

  2. Performance with uncertainty

    Every figure with its range of uncertainty, never as a single number alone.

  3. Calibration

    Whether a predicted risk matches how often the condition really occurs.

  4. Subgroups

    Performance by age, sex and pre-existing conditions, and any group put at a disadvantage.

  5. Robustness to missing and shifted data

    How the AI behaves when values are missing, or when patients and practice change.

  6. Comparison with simple clinical scores

    Whether the AI adds anything to the simple scores hospitals already use.

  7. Clinical meaning of the errors

    What the missed cases and the false alarms would mean for patients and staff.

  8. Recommendations and what to re-test

    What to change before use, and what to test again after the next update.

Every finding is linked to its evidence, and every run can be repeated.

Language models

Checks for medical chat and text systems.

Language models fail in their own ways. For medical chat assistants and text systems, the test bench checks these risks.

  • Invented answers that sound plausible
  • Wrong or made-up citations
  • Harmful advice
  • Prompt injection: instructions hidden in a question or a document
  • Consistency of the answers across languages

Languages matter: an answer that is safe in English must be safe in Arabic or Bengali too.

Where we are

Being built, open to pilot partners.

Pilot programmeOffered to a small number of pilot partners while the test bench matures.

The digital test bench is a method under construction. Its first proof of concept is an early warning for sepsis.

It is open to pilot partners among hospitals and AI vendors: a vendor’s AI, measured on a hospital’s own retrospective data before it goes live.

Real health data is used only under a written agreement and with a legal basis, in an agreed secure environment, retrospectively and without influence on patient care.

Bring us the question. We bring three views on it.

Tell us what you need to decide. We scope the question, the disciplines it needs and what the report will cover.